E90E90E90E90 OPERATORS MANUAL MC2 AUDIO Ltd., Units 6-8, Kingsgate, Heathpark Industrial Estate, HONITO
10Connections INPUTS Note: This amplifier is wired to the latest industry recommendations. PIN1 is connected directly to the chassis/main
11OUTPUTS Channel A and Channel B speaker outputs are via Neutrik Speakon connectors. 4 poles are used. 2-pole (NL2FC) or 4-pole (NL4FC) connectors
12Temperature Control The cooling fans respond to temperature sensors within the unit to maintain a safe operating temperature. In th
13AIR FILTER The filter behind the air intake apertures on the front of E SERIES amplifiers should be cleaned or replaced periodi
14 Power requirements The E90 can be supplied for nominal mains voltage of 115V or 230V. An internal link can be set to either 100V or 120V for th
2 CONTENTS EC DECLARATION OF CONFORMITY 3 IMPORTANT SAFETY INSTRUCTIONS 4, 5, 6, 7
3
4Important Safety Instructions 1) Read and keep these instructions. 2) Heed all warnings. 4) Follow all instructions. 5) Do not block any ven
5WARNING To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture. WARNING To prevent injury, th
6 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructi
7 1. Lisez ces instructions. 2. Gardez ces instructions. 3. Faites attention à tous les avertissements. 4. Suiv
8INSTALLATION EMC (RF Emissions) The high frequency resonant converters in the E Series amplifiers have been designed to have very low radio freque
9General Information Your E90 power amplifier utilises a proprietary designed switching output (Class-D), which couples the advantages of extremely