Connecting To Your Amplifier: Bridged (Mono) Operation
Pairs of channels may be independently bridged — channel pair A&B, and/or channel pair
C&D.
The method is the same for both channel pairs:
Supply signal to Channel A or C input only and push in the appropriate rear panel switch
marked “BRG A&B” or “BRG C&D”.
Use Channel A or C’s Output Speakon connector and connect as follows:
Pin 2+: Hot
Pin 1-: Cold
When operating in bridged mode, the minimum impedances are doubled.
The minimum load in bridged mode is 4 ohms.